RAID6CHECK(8)		    System Manager's Manual		 RAID6CHECK(8)

NAME
       raid6check - check MD RAID6 device for errors aka Linux Software RAID


SYNOPSIS
       raid6check <raid6 device> <start stripe> <number of stripes>


DESCRIPTION
       RAID6 devices in which one single component drive has errors can use
       the double parity in order to find out which component drive.  The
       "raid6check" tool checks, for each stripe, the double parity
       consistency, reports mismatches and, if possible, which component drive
       has the mismatch.  Since it works at stripe level, it can report
       different drives with mismatches at different stripes.

       "raid6check" requires a non-degraded RAID6 MD device as first
       parameter, a starting stripe (usually 0) and the number of stripes to
       be checked.  If this third parameter is also 0, it will check the array
       up to the end.

       "raid6check" will start printing information about the RAID6, then for
       each stripe, it will report the parity rotation status.	In case of
       parity mismatches, "raid6check" reports, if possible, which component
       drive could be responsible. Otherwise it reports that it is not
       possible to find the component drive.

       If the given MD device is not a RAID6, "raid6check" will, of course,
       not continue.

       If the RAID6 MD device is degraded, "raid6check" will report an error
       and it will not proceed further.

       No write operations are performed on the array or the components.
       Furthermore, the checked array can be online and in use during the
       operation of "raid6check".


EXAMPLES
	 raid6check /dev/md0 0 0
       This will check /dev/md0 from start to end.

	 raid6check /dev/md3 0 1
       This will check the first stripe of /dev/md3.

	 raid6check /dev/md1 1000 0
       This will check /dev/md1 from stripe 1000 up to the end.

	 raid6check /dev/m127 128 256
       This will check 256 stripes of /dev/md127 starting from stripe 128.

	 raid6check /dev/md0 0 0 | grep -i error > md0_err.log
       This will check /dev/md0 completely and create a log file only with
       errors, if any.


FILES
       "raid6check" uses directly the component drives as found in /dev.
       Furthermore, the sysfs interface is needed in order to find out the
       RAID6 parameters.


BUGS
       Negative parameters can lead to unexpected results.

       It is not clear what will happen if the RAID6 MD device gets degraded
       during the check.


       The latest version of raid6check should always be available from

	      https://www.kernel.org/pub/linux/utils/raid/mdadm/

       Related man pages:

       mdadm(8) mdmon(8), mdadm.conf(5), md(4).